OpenHydro Bench

SWMM 5.1.15 previous release

EPA SWMM 5.1.15, the release before 5.2: on the parity tests compared with SWMM 5.2.4, on the exact tests scored like any other engine.

Scored for compatibility with the current release, not for physics. Ran 15 tests; worked examples and previous releases are shown beside the leaderboard, not ranked on it. Score cards from: EPA SWMM 5.1.15.

Compare SWMM 5.1.15 with another model →

TestDifference, rankChecks
Sewer pipes running part full
A1D-001
#2= 0.027 % off
of 5 models
• Worst depth error 0.27 mm off; • Typical flow error < 0.0001 % off
Sewer pipes running full
A1D-002
#2= 0.034 % off
of 5 models
• Worst depth error 0.4 mm off; • Typical flow error < 0.0001 % off
Tank emptying through an outlet
A1D-003
#3= 0.33 % off
of 5 models
• Worst depth error 1.4 mm off; • Worst flow error < 0.0001 m³/s off
Pump working on its curve
A1D-004
#1= under 0.01 % off
of 5 models
• Worst depth error < 0.0001 mm off; • Worst flow error < 0.0001 m³/s off
Backwater up a sewer
A1D-005
#1= 0.025 % off
of 5 models
• Worst depth error 0.3 mm off; • Typical flow error < 0.0001 % off
Gentle backwater in a channel
A1F-001
#1= under 0.01 % off
of 15 models
• Average depth error 0.022 mm off; · Water conserved 0.002 % error
Dam break onto dry ground
A1F-010
#9= 11 % off
of 20 models
• Flood front 41.2 m behind exact; · Water conserved 0.036 % error
Dam break into shallow water
A1F-011
#17= 6.7 % off
of 20 models
• Average depth error 3.7 cm off; · Water conserved 4.1 % error
Standing hydraulic jump
A1F-020
#7= 102 % off
of 9 models
• Depth profile 102 % off; · Jump stays put 29 % error
Calm flow over a hump
A1F-040
#9= 174 % off
of 12 models
• Average depth error 1.45 m off; • Average flow error 7.71 m²/s off
Flow speeding up over a hump
A1F-041
#11= 189 % off
of 12 models
• Average depth error 56 cm off; • Average flow error 2.89 m²/s off
Hump with a hydraulic jump
A1F-042
#11= 322 % off
of 12 models
• Average depth error 29 cm off; • Average flow error 0.579 m²/s off
Still lake around an island
A1F-043
#8= 0.047 % off
of 13 models
• Worst velocity error 0.00047 m/s off; • Average depth error 0.012 mm off
Sewer network routing
B-EXTRAN-001
#1= under 0.01 % off
of 4 models
• Peak depths 0 % off; • Volumes 0 % off
Pump station switched by rules
B-RTC-001
#1 under 0.01 % off
of 4 models
• Peak depths 0 % off; • Volumes 0 % off; · Timing 0 s off