OpenHydro Bench

OpenSWMM 6 vs SWMM 5.2.4

OpenSWMM Engine v6 (HydroCouple's SWMM 6, pre-release), compared with SWMM 5.2.4.

Scored for compatibility with the current release, not for physics. Ran 2 tests; worked examples and previous releases are shown beside the leaderboard, not ranked on it. Score cards from: OpenSWMM Engine 6.0.0a4.dev1.

How it is run, and what was found →

Compare OpenSWMM 6 with another model →

TestDifference, rankChecks
Sewer network routing
B-EXTRAN-001
#1= under 0.01 % off
of 4 models
• Peak depths 0 % off; • Volumes 0 % off
Pump station switched by rules
B-RTC-001
#2 51 % off
of 4 models
• Peak depths 51 % off; • Volumes 5.1 % off; · Timing 180 s off

Pumps switch the same 74 times, but one node peaks 50 % higher than in SWMM 5.2.4, at a different time; worth a look by the OpenSWMM developers.